fccli(1m)
fccli - FibreVault Status/Configuration Command Line Interface
As shipped in IRIX 6.5.5. Unchanged since IRIX 6.5.
NAME fccli - FibreVault Status/Configuration Command Line Interface SYNOPSIS The command line syntax of fccli takes multiple flavors depending on the use. fccli getversion [-h hostname] fccli getstatus [-h hostname] [-c channel-ID [-e enclosure-ID]] fccli command [-h hostname] -c channel-ID -t tid_1 [tid_2 .. [tid_n]] where command is one of the following: insert, remove, ledon, ledoff, flash, bypass, unbypass. DESCRIPTION The fccli command is a user front end to fcagent which collects status of all FibreVault enclosures and allows for configuration changes. COMMANDS getversion this command will report the version level of fcagent. getstatus this command reports status of FibreVault enclosures. The interface is in the form of a hierarchy where the user can get brief summary channel status at one extreme and detailed enclosure status at the other extreme. remove this command will prepare a drive for physical removal, i.e. will spin-down the specified disk drive, and bypass it to logically remove it from the FC loop. insert this command will prepare a drive for operation, after being physically introduced into the enclosure, i.e. will unbypass it to logically introduce it onto the FC loop and spin it up. ledon this command will turn "ON" the amber "LED" associated with the specified disk device. ledoff this command will turn "OFF" the amber "LED" associated with the specified disk device. flash this command will "FLASH" the amber "LED" associated with the specified disk device. This "flashing" mode will persist until either an ledon or ledoff command is issued. bypass this command will logically remove the specified disk device from the FC loop. unbypass this command will logical introduce the specified disk device onto the FC loop. OTHER COMMAND LINE OPTIONS -h hostname use this option to communicate with an instance of fcagent running on a remote machine. -c channel-ID use this option to direct a command at a particular FC channel. -e enclosure-ID use this option (getstatus command only) in conjunction with the -c option to obtain more detailed status about a particular enclosure. -t tid_1 [tid_2 .. [tid_n]] use this option(s) (insert, remove, ledon, ledoff, flash, bypass, unbypass commands only) in conjunction with the -c option to direct an action at a particular drive or set of drives. EXAMPLES Obtaining the revision level of the instance of fcagent running on remote machine betelguese: fccli getversion -h betelguese sample output: FC JBOD Agent version 1.0, Mon May 19 17:16:48 PDT 1997 Obtaining a brief channel status summary: fccli getstatus sample output: CHANNEL | DRIVES POWER FANS PEER LCC --------+----------------------------------------- 24 | OK FAIL OK OK 25 | The example shows that channel 24 has one or more enclosures reporting a power supply fault. Channel 25 shows no status which indicates one of three possibilities. o There are no FC device(s) connect to the channel. o There are no FibreVaults(s) connect to the channel (e.g. fibre RAID may be connected). o There is a communication problem with the FibreVault. Obtaining a more detailed enclosure summary of channel 24: fccli getstatus -c 24 sample output: ENCLOSURE | DRIVES POWER FANS PEER LCC ----------+----------------------------------------- 4 | OK FAIL OK OK 5 | OK FAIL OK OK The example shows two connected FibreVault enclosures connected to channel 24, IDs 4 and 5, with a power supply fault in each. It should be noted that fccli cannot differentiate between a failed power supply and one that is present but powered down. Obtaining a detailed status of enclosure 4 on channel 24: fccli getstatus -c 24 -e 4 sample output: Enclosure 4, status FAIL Vendor ID: CLARiiON Product ID: DISK ENC LCC SN#: LCC Mfg. Date: LCC code rev: 003 FRUs: 10 disk slot(s) 1 fan slot(s) 2 power supply slot(s) 1 peer LCC slot(s) +---------------------------------------+------+ | [ 4] FAIL | | +---------------------------------------+ | | | | | | | | | | | | P | | O | O | O | O | O | O | O | O | B | B | E L | | K | K | K | K | K | K | K | K | P | P | E L | | 40| 41| 42| 43| 44| 45| 46| 47| 48| 49| R C | +---------------------------------------+ | | FANS OK | OK | | PS0 FAIL PS1 OK | | +---------------------------------------+------+ The example shows a power supply fault on power supply FRU 0. Additionally, disk FRUs 48 and 49, although physically present, have been bypassed. Illuminating the amber LEDs associated with disk FRUs 45-49 on channel 24: fccli ledon -c 24 -t 45 46 47 48 49 FILES /usr/sbin/fccli SEE ALSO fcagent(1M)