NAME
     pmview+ - configuration file format for performance metrics 3D
     visualization back-end

DESCRIPTION
     This man page describes version 2.1 of pmview+ configuration file format,
     which is the extention of pmview(1) configuration format version 2.1.

     The configuration format supports metrics from multiple hosts or
     archives.  A configuration file can specify metrics without a source,
     with different hosts and different archives.  However, a configuration
     file that contains archives may only have one archive for anyone host.
     When in ``replay'' mode, any metrics with host specific sources require
     an archive to be specified for that host on the command line or as a
     source to a previous metric.  The archive must be the same archive (based
     on a string comparison of the archive names) of any archives specified in
     the configuration file for the same host.

     The time controls will list all hosts that are specified on the command
     line and the configuration file in the timezone listing (see pmtime(1)).

     The configuration file format is based on a two-dimensional grid which
     can contain a variety of bars, stacks, links, pipes, labels and other
     grids.  The grids resize each column and row to match the size of the
     largest item in that column or row.  A configuration file that contains
     only one object does not require a grid. The pmview+ configuration file
     starts with an identification header in the first non-comment line:

          pmview Version 2.1 [command_line]

     The optional command_line should be the command line with which the tool
     was launched, if the configuration file has been generated by another
     tool.  This is useful for applications that are to be restarted
     automatically on the next login, after the user has logged out while
     pmview+ was still running.  Care should be taken to ensure that the
     command specified is either a full pathname or will be found on the PATH
     available at login.

     All lines which begin with ``#'' are treated as comments and ignored.
     Otherwise, all spaces, tabs and newlines are treated as white space so
     multiple commands may be on the same line.

     The syntax for specifying values in the configuration file is consistent
     for all commands, namely:

     color
         A color must be either a X(1) color name, a X(1) numerical color, or
         three normalized real values representing the saturation of red,
         green and blue.  For example, the following colors are identical:

               red
               rgbi:1.0/0.0/0.0
               1.0 0.0 0.0

     int An integer.

                                                                             1





PMVIEW+(4)                                                          PMVIEW+(4)



     metric
         A metric consists of an optional source (host or archive), the metric
         name, an optional instance list immediately after name, followed by
         the maximum (or normalization value).  A colon (``:'') is used to
         separate a host name from the metric, and a forward slash (``/'') to
         separate an archive name from the metric.  Instances are enclosed in
         square brackets and comma separated.  Each instance may be enclosed
         in quotes.

         For example, some legal metrics are:

               kernel.all.cpu.idle 4000
               myhost:kernel.all.cpu.idle[cpu0,"cpu3"] 1000.0
               /path/to/myarchive/kernel.all.cpu.idle[cpu1] 1000

         To assist the process of matching instance names, two further
         comparisons are made beyond a simple string comparison.  If the
         instance name contains spaces, only the first word in the instance
         name is required to match the instance, assuming that the first word
         is unique.  If the first word is not unique, only the first matching
         instance will be selected.  The second comparison occurs if the first
         word is a number with leading zeros.  Any leading zeros will be
         skipped before comparing the first word again.  This permits process
         ids used in the proc metrics to be easily matched, without specifying
         the entire instance name.  For example, to visualize the user and
         system time of init use the metric specification

               proc.psusage.utime[1]    1000
               proc.psusage.stime[1]    1000

     name
         A name for an object which may be referred to later in the
         configuration file.  Names must be a single word consisting of all
         alphanumeric characters, as well as underscores, dashes and colons.
         It is recommended that names do not begin with an underscore as this
         may be interpreted as a keyword.

     pos This is the position of the object within the grid.  The syntax of a
         position is:


          [ [x z] [ [width depth] [alignment] ] ]

            x      The horizontal coordinate (left to right) of the object,
                   starting at 0.  The default x is 0.

            z      The vertical coordinate (top to bottom) of the object,
                   starting at 0.  The default z is 0.

            width  The number of columns occupied by the object.  The default
                   width is 1.

            depth  The number of rows occupied by the object.  The default
                   depth is 1.

            alignment
                   The edge or corner that the object is aligned with.
                   Possible alignments include: north, south, east, west,
                   northeast, northwest, southeast, southwest and center.
                   Abbreviations like se and SE are also accepted.  The
                   default alignment is center.

                   The size of an object may not be known as the number of
                   instances for some metrics will vary between hosts and PMDA
                   configurations.  Therefore, the position of the object can
                   be used to specify the likely size of the object, so that
                   the position of the surrounding objects is appropriately
                   adjusted.

                   The following are legal positions:

                   0 5    The object is centered at grid position 0,5
                          occupying 1 grid square.

                   1 2 north
                          The object is aligned with the north edge of
                          position 1,2 occupying 1 grid square.

                   2 2 2 1 east
                          The object is aligned to the eastern edge of
                          position 3,2 and occupies 2 grid squares (2,2 and
                          3,2).

     string
         A string is a series of characters enclosed in double quotes.  A
         string may not contain newlines or escaped double quotes.


     There are several parameters that may affect the size, shape and color of
     objects when they are displayed.  These parameters are scoped so that
     they only alter objects defined later in the same scope.  Therefore,
     parameter settings at the top of a configuration file affect the entire
     scene, unless they are changed later in the file.  Most of these
     parameters are also resources.

     _barLength int
         The side length of the _bar and _stack blocks.  Default is 28.

     _barHeight int
         The maximum height of a _bar and _stack blocks.  Default is 80.

     _baseColor color
         The color of _bar, _grid and _stack base planes.  Default is
         rgbi:0.15/0.15/0.15.
     _baseHeight int
         The height of _bar, _grid and _stack base planes.  Default is 2.

     _gapWidth int
         The gap between blocks in a _bar object in the X-axis.  The default
         is 8.

     _gapDepth int
         The gap between blocks in a _bar object in the Z-axis.  The default
         is 8.

     _gapLabel int
         The gap between the base of a _bar object, and any metric or instance
         labels.  The default is 6.

     _gridWidth int
         The minimum width of a _grid column.  The default is 20.

     _gridDepth int
         The minimum depth of a _grid row.  The default is 20.

     _labelMargin int
         The margin around a _label object.  The default is 5.

     _labelColor color
         The color of _label and _bar labels.  The default is white.

     _marginWidth int
         The extra width of a _bar, _grid and _stack base plane beyond the
         objects on the plane.  The default is 8.

     _marginDepth int
         The extra depth of a _bar, _grid and _stack base plane beyond the
         objects on the plane.  The default is 8.

     _pipeLength int
         Total length of a _pipe.  The default is the value of _barHeight.

     _scale real
         The scale applied to the entire scene.  This parameter may not be
         used within any objects, only at the top of the configuration file.
         The default is 1.0.

     To simplify the specification of colors, a _colorList and a _colorScale
     may be used to define colors for an object which has metrics associated
     with it, i.e. _bar, _stack or _pipe.  A color list may be defined within
     an object, or named and defined at the top of a configuration file.  A
     named color list may then be referenced within multiple objects:

     _colorList name ( color [color...] )
         Associate the colors with the color list name.  The assignment of
         colors to blocks depends on the type of an object.  For example, the
         color list called foo has the same color three times:

         _colorList foo ( red rgbi:1.0/0.0/0.0 1.0 0.0 0.0 )


     _colorScale name color ( color real [color real...] )
         Associate the colors and reals with the color list name.  The initial
         color is the default color of the object.  The object will change
         color to the other colors when the normalized value of the object is
         equal to or greater than each real.  Therefore, each real must be
         larger than the previous real, and should be in the range 0.0 to 1.0.
         This scale gradually changes from blue to red:

         _colorScale coldToHot blue ( rgbi:0.5/0.0/1.0 0.3
                                      purple 0.6
                                      rgbi:1.0/0.0/0.5 0.8
                                      red 0.95)

     There are several different object types which could be found in a
     pmview+ scene: _bar, _stack, _pipe, _grid, _link, and _label.  There is
     also _xing which is a special type of the _link.  The _bar, _stack and
     _pipe objects are modulated by metric values, a _label is fixed text,
     _link and _xing are interconnects and a _grid is a container of objects,
     including other _grid objects, which controls the layout of the scene.  A
     _grid object is only required if there are two or more objects in the
     scene.

     _bar, _grid and _stack objects may have base planes which provide a point
     of reference for the blocks as they change height.  A label can be
     applied to the base plane _grid object if it is _shown with:

               _baseLabel name|string

     _baseLabel should be used within the scope of the relevant _bar, _grid or
     _stack object.  The first ``\n'' characters in the string will be
     replaced by a new line.  Subsequent ``\n'' characters will be ignored.

     For a scene to be valid it must contain at least one modulated object.

     The objects are defined as:

     _bar [options] ( [metric-list] [color-list] [label-list] )
         A _bar object represents a collection of blocks.  The number of
         blocks depends on the number of metrics and metric instances assigned
         to the object.  By default, the blocks are modulated by changing the
         height of each block.  Alternatively, blocks may be modulated by
         changing color, or both height and color.  Each color in the color-
         list is assigned to each metric.  Therefore, multiple instances of
         the one metric will have the same color.  The options that may be
         passed to a _bar object are:

         pos The position of the _bar object within the current _grid object.

         _col|_row
             Position the blocks so that each instance is in a column (_col)
             or a row (_row).  This implies that each different metric is in a
             separate row or column, respectively.  The default is _col.

         _show|_hide
             Is the base plane visible? Default is _show.

         _ymod|_colormod|_colorymod
             Modulate the blocks by adjusting their height (_ymod), color
             (_colormod) or both height and color (_colorymod).

         _cube|_cylinder
             Set the shape of the blocks.  The default is _cube.

         _groupbymetric|_groupbyinst|_groupbyrow||groupbycol
             Set the grouping of blocks when launching other tools. For tools
             like pmchart(1) some views may generate many small charts which
             cannot be drawn entirely within the screen.  Another problem is
             it may be more appropriate to generate charts with the same
             instance in each chart, rather then the same metric.  The group
             specifiers control the algorithm used so that a separate chart
             will be drawn for each _metrics specification (_groupbymetric),
             for the first, second etc. instance of each _metric
             (_groupbyinst), or by the rows and columns of the _bar object
             depending on _row or _col.  The default is _groupbymetric.

         The options must be specified in this order, although preceding
         options are not required.  Therefore, this is legal:

               _bar _hide _cylinder ( ... )

         The metrics, colors and labels are specified within the brackets in
         any order.  Only the metric-list is mandatory.

         metric-list
             A _bar metric list contains a list of metric names, normalization
             values and an optional label for the metric:

             _metrics ( metric real [string] [metric real [string]...] )


         color-list
             A _bar color list may be a named color list that was defined
             earlier, or an unnamed color list.  A _colorScale list should be
             used when using _colormod or _colorymod modulation.  Therefore,
             the syntax for color lists within a _bar object are any of:

             _colorList name
             _colorList ( color [color...] )
             _colorScale name
             _colorScale color ( color real [color real...] )

         label-list
             In addition to labels for each metric in the metric-list, metric
             and instance labels may be defined using _metriclabels and
             _instlabels statements.  The position of the labels around the
             _bar object depends on the _row or _col orientation of metrics
             and instances, and whether the label is read _towards the _bar
             object, or _away.  The default is _towards.

             _metriclabels [_away|_towards] ( name|string [name|string...] )
             _instlabels [_away|_towards] ( name|string
             [name|string...] )


     _grid [pos] [_show|_hide] ( objects )
         A _grid object is a container for objects, including other _grid
         objects.  The rows and columns of a _grid object are resized to the
         largest object in the row or column.  If an object spans multiple
         rows and/or columns, those rows and columns may be partly resized to
         contain the object.  However, the resizing of rows and columns for
         objects occupying multiple rows and columns occurs after resizing for
         objects occupying only one grid square.

         A collision between objects occupying the same squares will be
         reported as an error message and the later object will be ignored.

         The options to a _grid object control the position (pos) of the _grid
         object in the parent _grid, and indicate whether to _show or _hide
         the _grid base plane.  By default, the base plane is hidden.

         The parameters described above may be specified within the brackets
         of a _grid object, however they only apply to the objects within the
         _grid, not the _grid itself.  For a parameter to be applied to a
         _grid object, it must be specified before the _grid object
         declaration.


     _label [options] string
         A _label object draws the contexts of string at the location,
         orientation and size specified in the options:

         pos The position of the _label object in the current _grid object.

         _left|_right|_up|_down
             The orientation of the string.  The direction indicates the
             direction the label is read.  Therefore, _right is the default
             since the string is read from left to right.

         _small|_medium|_large
             The font size.  The default is _medium.


     _link pos [string]
         A _link object draws a straight or L-shaped horizontal round ``pipe''
         with diameter equal to 80% of the _baseHeight of an enclosing _grid.
         The properties of the object are defined by the options:


         pos sets both the position of the _link on the grid and its shape.
             _link starts in the column and row on the _grid specified by
             first two numbers in the pos and spans the number of columns and
             rows set by the second two numbers. The alignment value is used
             to decide the orientation of the link (links are always aligned
             at the center):  east and west links are straight and going from
             left to right, north and south links are straight and going from
             far end of the grid to near end, northeast, northwest, southeast
             and southwest links are L-shaped and connect the corresponding
             points of the compass, i.e. a northeast link takes on the general
             shape of the Latin letter ``L''.

         string
             sets the ``tag'' for the _link which will be displayed in the
             text window when the pointer is over the link.



     _pipe pos ( [metric-list] [color-list] [tag] )
         A _pipe object represent a set of cylinders, placed on top of each
         other and oriented parallel to the base plane. The diameter of a
         _pipe is equal to 80% of _baseHeight.  The number of blocks is
         dependent on the number of metric instances in the metric-list.  The
         colors in the color-list are assigned in turn to each cylinder in the
         _pipe.  The length of the _pipe is defined by the _pipeLength.


         pos defines the position of the _pipe on the enclosing _grid and its
             orientation with alignment field used to define at which end of
             the pipe to stack the colored cylinders. The cylinders are
             stacked at the corresponding point of the compass and the pipe's
             direction is from the point of the compass towards the center of
             the compass. Only east, west, north, and south are valid values
             for the pipe's alignment.

     The metrics, colors and label may be specified within the brackets in any
     order.  Only the metric-list is mandatory.

     metric-list
         A _pipe metric list contains a list of metric names and normalization
         values:

         _metrics ( metric real [metric real...] )


     color-list
         A _pipe color list may be named color list that was defined earlier,
         or an unnamed color list:

         _colorList name
         _colorList ( color [color...] )


     tag A _pipe may have a ``tag'' for the filler block (unanimated block on
         the ``other'' end of the pipe) which will be displayed in the text
         window when the pointer is over that end of the pipe.

         _pipeTag name|string


     _stack [options] ( [metric-list] [color-list] [label] )
         A _stack object represents a set of blocks placed vertically on top
         of each other.  The number of blocks is dependent on the number of
         metric instances in the metric-list.  The colors in the color-list
         are assigned to each block in the _stack.  By default, the height of
         the _stack will be the sum of the height of each block.  The options
         that may be passed to a _stack object are:

         pos The position of the _stack object within the current _grid
             object.

         _show|_hide
             Is the base plane visible? Default is _show.

         _utilmod|_fillmod
             Force the height of the stack to always be the maximum height.
             This is achieved by normalizing the height of each block
             (_utilmod), or by adding a grey block to the top of the stack
             (_fillmod).

         _cube|_cylinder
             Set the shape of the blocks.  The default is _cube.

         The options must be specified in this order, although preceding
         options are not required.  Therefore, this is legal:

               _stack 1 1 _north _utilmod ( ... )

         The metrics, colors and label may be specified within the brackets in
         any order.  Only the metric-list is mandatory.

         metric-list
             A _stack metric list contains a list of metric names and
             normalization values:
             _metrics ( metric real [metric real...] )


         color-list
             A _stack color list may be named color list that was defined
             earlier, or an unnamed color list:

             _colorList name
             _colorList ( color [color...] )


         label
             A _fillmod type _stack may have a label for the filler block:

             _stackLabel name|string


     _xing col row columns rows dir1 ... dir4
         A _xing is a special kind of link which is used to draw a pair of
         links which cross each other. To convey the visual impression that
         the links do not join, one of the links is drawn as a ``broken''
         cylinder.  col and row define the position on the enclosing grid.
         columns and rows define the size of the bounding box. The end points
         of the crossing cylinders are placed exactly in the center of the
         corner cells of the bounding box and four small cylinders or stubs
         are used to join the perimeter of the bounding box with the end
         points on the crossing cylinders. Four dir values define the
         orientation of the stubs, starting at the upper left corner of the
         _xing and proceeding clockwise, such that respective stubs are used
         to join the point of the compass with the center on the cell (see
         example).

EXAMPLE
     This simple example illustrates the use of parameters and different
     object types:

          pmview Version 2.1
          # Use a lighter grey for the base planes
          _baseColor rgbi:0.5/0.5/0.5

          # Define colors for CPU object
          _colorList cpu ( blue2 red2 yellow2 cyan2 green2 )

          # The top grid object, but hide it from view
          _grid _hide (

          # Show the current load in a bar object
             _bar 0 0 (
                 _baseLabel "Load averages over a\n1, 5 and 15 minute interval"
                 _metrics (
                    kernel.all.load[1] 1 "1"
                    kernel.all.load[5] 1 "5"
               kernel.all.load[15] 1 "15"
               )
               _colorList ( blue blue blue )
              )

          # Add a label below the load bars
              _label 0 1 "Load"

          # Change the color of the base plane for later objects
              _baseColor pink

          # Show the CPU usage over all CPUs in a utilization stack
              _stack 2 0 _south _utilmod (
               _baseLabel "CPU Utilization over all CPUs"
               _metrics (
                    kernel.all.cpu.user 1000
                    kernel.all.cpu.sys 1000
                    kernel.all.cpu.intr 1000
                    kernel.all.cpu.wait.total 1000
                    kernel.all.cpu.idle 1000
               )
               _colorList cpu
              )

          # Add a label below the CPU stack
              _label 2 1 "CPU"

          # Create a separate grid for links and pipes
              _marginWidth 1
              _marginDepth 1
              _gridSpace  12
              _grid 0 3 5 4 _hide (
               _pipeLength 12
               _baseHeight 12

               # Add  a pipe and a link with western orientation
               _pipe 0 0 west (
                   _pipeTag "West pipe"
                   _metrics (
                    kernel.all.cpu.user 1000
                    kernel.all.cpu.sys 1000
                    kernel.all.cpu.idle 1000
                   )
                   _colorList cpu
               )

               _link 0 2 west "West link"

               # Add xing
               _xing 1 0 3 3 west east east west

               # Add a link and a pipe with eastern orientation
              _pipe 4 0 east (
                   _pipeTag "East Pipe"
                   _metrics (
                    kernel.all.cpu.user 1000
                    kernel.all.cpu.sys 1000
                    kernel.all.cpu.idle 1000
                   )
                   _colorList cpu
               )
               _link 4 2 east "East link"
              )
          )

SEE ALSO
     pmview(1) and pmview+(1).