SCSetup(3)
SCSetup - set scanning parameters
As shipped in IRIX 6.5.30. Unchanged since IRIX 6.5.
NAME SCSetup - set scanning parameters SYNOPSIS #include <stdio.h> #include <scanner.h> int SCSetup(SCANNER *s, int preview, SCDATATYPE *type, int rmetric, float xres, float yres, int wmetric, float x, float y, float width, float height); DESCRIPTION SCSetup transfers scanning parameters to the scanner driver, in preparation for a subsequent call to SCScan or SCScanFD. s specifies a connection to a scanner driver obtained from a call to SCOpen(3), SCOpenFile(3), or SCOpenScreen(3). preview should be non-zero if these are parameters are for a preview, or 0 if they are for a final scan. If set, this flag is an indication to the driver to prefer speed over image quality in order to enable a fast preview mode. If preview is zero, the scanner driver is instructed to prefer image quality over speed. type is the type of data to be scanned. It must be one of the types supported by the scanner. See SCGetDataTypes(3) for information on determining which types are supported by a scanner. rmetric is set to either SC_INCHES or SC_CENTIM, depending on whether the resolution is specified in inches or centimeters. xres specifies the horizontal scanning resolution, and yres specifies the vertical scanning resolution. xres and yres must be within the limits supported by the scanner driver. See SCGetMinMaxRes(3) for information about getting these limits. wmetric is set to either SC_PIXELS, SC_INCHES, or SC_CENTIM, depending on whether the scan area is specified in pixels, inches, or centimeters. x and y specify the coordinates of the upper left corner of the scan area, and width and height specify the size of the scanning area. The scanning area must lie within the scannable area supported by the scanner. See SCGetPageSize(3) for information about getting the scannable area. If wmetric is set to SC_PIXELS, the scanner driver is required to return exactly width pixels per scan line and exactly height scan lines when scanning. After calling SCSetup, SCGetScanSize(3) should be called to determine the actual size in pixels of the scanning area, and then SCScan(3) or SCScanFD(3) should be called to start scanning. RETURN VALUE SCSetup returns 0 if successful. If an error occurs, SCSetup returns -1 and sets SCerrno to indicate the cause of the error. EXECUTION ERROR CODES SCSetup will fail under the following circumstances. SCENOTSUPPORTED Unsupported operation SCEBADTYPE Illegal data type specified SCENOMEM Out of memory SCEBADRES Unsupported resolution specified SCEBADPARAM Bad scanning parameter SCEBADMETRIC Unsupported metric SCEDEV Scanner driver error SCECOMM Error communicating with scanner driver SCEDRVMSG Driver specific error. SCErrorString(3) will return a custom message supplied by the scanner driver SEE ALSO libscan(3), SCOpen(3), SCGetDataTypes(3), SCGetScannerRes(3), SCGetMinMaxRes(3), SCGetPageSize(3), SCScan(3), SCScanFD(3).