SCSetup(3)

SCSetup - set scanning parameters

Showing IRIX 6.5.30 (default release). Unchanged since IRIX 6.5.

NAME
     SCSetup - set scanning parameters

SYNOPSIS
     #include <stdio.h>
     #include <scanner.h>

     int SCSetup(SCANNER *s, int preview, SCDATATYPE *type,
                 int rmetric, float xres, float yres,
                 int wmetric, float x, float y, float width, float height);

DESCRIPTION
     SCSetup transfers scanning parameters to the scanner driver, in
     preparation for a subsequent call to SCScan or SCScanFD.

     s specifies a connection to a scanner driver obtained from a call to
     SCOpen(3), SCOpenFile(3), or SCOpenScreen(3).

     preview should be non-zero if these are parameters are for a preview, or
     0 if they are for a final scan.  If set, this flag is an indication to
     the driver to prefer speed over image quality in order to enable a fast
     preview mode.  If preview is zero, the scanner driver is instructed to
     prefer image quality over speed.

     type is the type of data to be scanned.  It must be one of the types
     supported by the scanner.  See SCGetDataTypes(3) for information on
     determining which types are supported by a scanner.

     rmetric is set to either SC_INCHES or SC_CENTIM, depending on whether the
     resolution is specified in inches or centimeters.  xres specifies the
     horizontal scanning resolution, and yres specifies the vertical scanning
     resolution.  xres and yres must be within the limits supported by the
     scanner driver.  See SCGetMinMaxRes(3) for information about getting
     these limits.

     wmetric is set to either SC_PIXELS, SC_INCHES, or SC_CENTIM, depending on
     whether the scan area is specified in pixels, inches, or centimeters.  x
     and y specify the coordinates of the upper left corner of the scan area,
     and width and height specify the size of the scanning area.  The scanning
     area must lie within the scannable area supported by the scanner.  See
     SCGetPageSize(3) for information about getting the scannable area.

     If wmetric is set to SC_PIXELS, the scanner driver is required to return
     exactly width pixels per scan line and exactly height scan lines when
     scanning.

     After calling SCSetup, SCGetScanSize(3) should be called to determine the
     actual size in pixels of the scanning area, and then SCScan(3) or
     SCScanFD(3) should be called to start scanning.
RETURN VALUE
     SCSetup returns 0 if successful.  If an error occurs, SCSetup returns -1
     and sets SCerrno to indicate the cause of the error.

EXECUTION ERROR CODES
     SCSetup will fail under the following circumstances.

     SCENOTSUPPORTED          Unsupported operation

     SCEBADTYPE               Illegal data type specified

     SCENOMEM                 Out of memory

     SCEBADRES                Unsupported resolution specified

     SCEBADPARAM              Bad scanning parameter

     SCEBADMETRIC             Unsupported metric

     SCEDEV                   Scanner driver error

     SCECOMM                  Error communicating with scanner driver

     SCEDRVMSG                Driver specific error.  SCErrorString(3) will
                              return a custom message supplied by the scanner
                              driver

SEE ALSO
     libscan(3), SCOpen(3), SCGetDataTypes(3), SCGetScannerRes(3),
     SCGetMinMaxRes(3), SCGetPageSize(3), SCScan(3), SCScanFD(3).